What Type of Instalation? – Que tipo de instalação?

What Type of Instalation? – Que tipo de instalação?

maio 27
Number of View :7869

There are three types of installation for steam jet vacuum systems: Barometric Installation, Semi-Barometric Installation and Non-Barometric Installation.

Check in the pictures below, each one of them.

Existem três tipos de instalação de sistemas de vácuo com ejetores a vapor: Instalação Barométrica, Instalação Semi-Barométrica e Instalação Não Barométrica.

Veja nos desenhos abaixo cada uma delas.

Barometric Installation – Instalação Barométrica

Barometric Installation for direct contact condensers – Height of the barometric legs ~11 meters (at sea level)

Also applicable for surface condensers

Instalação Barométrica para condensadores de contato direto – Altura da perna barométrica ~11 metros (ao nível do mar)

Também aplicável a condensadores de superfície

Click “read more” for the complete article – Clique “read more” para o artigo completo


Like - Eu gostei!
11
Share
Effectively Design Shell-and-Tube Heat Exchangers – Projete Corretamente Trocadores de Calor Casco Tubo

Effectively Design Shell-and-Tube Heat Exchangers – Projete Corretamente Trocadores de Calor Casco Tubo

maio 20
Number of View :32189

I was looking for a picture of a single segmental baffle and a double segmental baffle to show a friend on Skype  how they operate, and accidentaly found this excellent article about the design of heat exchangers written by Rajiv Mukherjee from Engineers India Ltd. It was published by CHEMICAL ENGINEERING PROGRESS • FEBRUARY 1998.

©Copyright 1997 American Institute of Chemical Engineers. All rights reserved. Copying and downloading permitted with restrictions.

Click here to download the article

Clique aqui para fazer o “download’ do artigo

Eu estava procurando uma foto de uma chicana de segmento simples e uma duplo segmentar para mostrar como elas funcionam a um amigo no Skype , e acidentalmente encontrei este excelente artigo sobre o projeto de trocadores de calor escrito por Rajiv Mukherjee da Engineers India Ltd. Ele foi publicado na CHEMICAL ENGINEERING PROGRESS • Fevereiro 1998.

©Copyright 1997 American Institute of Chemical Engineers. All rights reserved. Copying and downloading permitted with restrictions.

Like - Eu gostei!
1
Share
Direct Contact Condensers or Surface Condensers? – Condensador de mistura ou condensador de superfície?

Direct Contact Condensers or Surface Condensers? – Condensador de mistura ou condensador de superfície?

maio 19
Number of View :30623

This article is based on material from Croll-Reynolds, Graham,  Koerting and Gea Wiegand.Clique “read more” at the botton of this post to read the whole article

Este artigo é baseado em material da Croll-Reynolds, Graham, Koerting e Gea-Wiegand. Clique em “read more” na parte inferior desta postagem  para ler o artigo completo.

When utilizing direct contact condensers,the process fluid comes into direct contact with the cooling water. Direct  contact condensers are insensitive tofouling and are, therefore, reliable in operation. It should be noted, however, that direct contact condensers cannot be recommended if ammonia is present in the process stream. The contact with the cooling water leads to the formation of non-dissolvable carbonates and fouling.

Like - Eu gostei!
12
Share
Choose the Right Vacuum Pump – Escolha a Bomba de Vácuo Correta

Choose the Right Vacuum Pump – Escolha a Bomba de Vácuo Correta

maio 13
Number of View :4341

Several devices are available for producing vacuum at a chemical-process plant.

Each has its own advantages and drawbacks. This article from Joe Aliasso was printed in the Chemical Engeeniring Magazine – March 1999.

Click here to download the article


Clique aqui para fazer o “download” do artigo

A geração de vácuo em processos químicos pode ser feita por vários tipos de bombas de vácuo.

Cada uma tem seus prós e contras.  Leia mais neste artigo de Joe Aliasso que foi publicado na revista Chemical Engineering de Março de 1999.

Like - Eu gostei!
11
Share
Vacuum Pumps Common Problems & Trubleshooting – Bombas de Vácuo – Problemas Mais Comuns e Soluções

Vacuum Pumps Common Problems & Trubleshooting – Bombas de Vácuo – Problemas Mais Comuns e Soluções

maio 05
Number of View :15698

Hello, I will try to start posting some information about other types of vacuum pumps than steam jet ejector and liquid ring vacuum pumps. I cannot remember where I found this paper, but you will find some useful information about rotary piston, dry screw and rotary vane vacuum pumps. The only reference I have is that it was extracted from the Chemical Industry Digest – 2007.

If you have some interesting article about vacuum pumps or vacuum aplications and want to share with your peers, please send me an e-mail and I will be glad to post it here, but note that it must be a technical article and not a sales paper.

Click here to download the article

Clicque aqui para fazer o “download” do artigo

Olá, eu vou tentar  postar  aqui algumas informações sobre outros tipos de bombas de vácuo , que não sejam ejetores a vapor  e bombas de vácuo de anel líquido. Não me lembro onde eu encontrei este artigo, mas você vai encontrar algumas informações úteis sobre bomba de vácuo de pistão rotativo, de parafuso e  de palhetas rotativas . A única referência que tenho é que ele foi extraído da Chemical Industry Digest – 2007.

Se você tem algum artigo interessante sobre bombas de vácuo ou sobre aplicações de vácuo e quer compartilhar com seus colegas, por favor me envie um e-mail e terei prazer em publicá-la aqui, mas lembre-se que ele deve ser um artigo técnico e não uma propaganda de venda.

Like - Eu gostei!
4
Share